Heated Sample Lines for Gas Analysis
Compare heated sample lines available from Exact Analytical for industrial applications, project integration and service support in Malaysia.
Categories

Maintain temperature up to 120 °C. External jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. Maximum length of heated line: 65 m. Inner core: PTFE, PFA or SS316, DN 4 to DN 8. Complete assembling sets with connection cable and silicone end caps or ready for use ex works. Second core for e.g. calibration gas as option.
Applications
Technical Specifications
Models & Variants

Maintain temperature regulated up to 185 °C. External jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. Ready for use. Interchangeable inner core for JHER. Second core for e.g. calibration gas as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Regulated heatable to max. 200 °C. External protection corrugated jacket of Polyamide. Heat insulation with thermo fleece. Ready for use. Interchangeable inner core for JH3FR. Second core for e.g. calibration gas as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Regulated heatable to max. 200 °C. External jacket flexible protection braid of polyamide. Heat insulation with silicone foam. Ready for use. Very flexible. Interchangeable inner core for JH3FGR. Second core for e.g. calibration gas as option. Integrated temperature controller as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Maintain temperature up to 120 °C. External jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. Maximum length of heated line: 65 m. Inner core: PTFE, PFA or SS316, DN 4 to DN 8. Complete assembling sets with connection cable and silicone end caps or ready for use ex works. Second core for e.g. calibration gas as option.
Applications
Technical Specifications
Models & Variants

Operating temperature regulated up to 180 °C. Antistatic external jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. 2 x Ex-Pt100 temperature sensors. Ready for use. Second core for e.g. calibration gas as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Ready for use. Wide thermal application area. Non flammable. With and without calibration gas core. Suitable for Ex zones.
Applications
Technical Specifications
Models & Variants

Heated JCT sample lines JH3F(R) and JH3FG(R) with integrated filter. Completely heated up to 200 °C. Filter housing stainless steel SS316Ti (PTFE- coated or Hastelloy as option). Ceramic filter element (5 um or 20 um). Jacket PA-corrugated hose or PA-braid. Fixed or interchangeable core. Completely assebled. Ready for connection with temperature controllers series HT.
Applications
Technical Specifications
Models & Variants

Ready for use combination of digital temperature controller JPXE4 and Solid State Relay. RGC with up to 30 A switching capacity. 4-digits LED-indication of set point and actual value For PT 100 and thermocouples JPXE4 for front panel mounting or optional for wall or rail mounting Solid State Relay RGC for rail mounting For single and 3 phase application SSR with varistor protection output Self-lifting terminals.
Applications
Technical Specifications
Models & Variants

Controller and limiter in one device. Status / Alarm contact. Suitable for self-regulating trace heaters. Suitable for resistance trace heaters.
Applications
Technical Specifications
Models & Variants

Long lifetime due to contactless switching. High switching capacity of 3680 W. Self programmable and free configurable. Pre-parameterised ex works on request. Robust compact design. Limiter function with permanent switch-off according to EN 60519. Switch-off temperature adjustable (0 °C up to 1000 ° C). Alarm relay for 1 A. PID controller. Wall mounting housing IP65. 2 - line illuminated LCD text display. Membrane keypad with 5 push-buttons. Alarm outlet with limit compensation. Controller outlet with Triac. Freely programmable. Auto tuning. Analog measured value outlet 0...10 V. Analog set point O...20 mA (optional).
Applications
Technical Specifications
Models & Variants

7-pole connector for JCT heated sample lines. Long lifetime due to contactless switching. High switching capacity of 2300 W. Robust compact design. Alarm relay for 1 A. PID controller. Wall mounting housing IP65. 2-line illuminated LCD text display. Membrane keypad with 5 push-buttons. Alarm outlet with limit compensation. Controller outlet with Triac. 2 & 3 wire RTD & TC Sensors. Analog temperature value outlet O...10 V. Analog set point O...20 mA (optional).
Applications
Technical Specifications
Models & Variants

Integrated fuses per load circuit. Long lifetime due to solid state relay. Supply voltage 115...230 VAC. Self optimising (autotuning). Programmable status contacts. Easy installation and set up. High reliability. Forced cooled unit for use up to 50 °C ambient temperature. Plug & play temperature controller. Up to 32 A switching capacity per circuit. Very high load capability up to 6,9 KW per heater circuit. Four-digits LED indication of set point and actual value. RTD Pt100 2W or 3W and thermocouples. One phase and multiple phase applications. SSR with varistor protection output. Compact design 3 HU 19" aluminum rack mount housing.