Neutronics
Explore Neutronics oxygen and refrigerant analysis instruments and related product families available through Exact Analytical in Malaysia. Compare models, applications and technical documents with local consultation, integration and service support.
Exact Analytical is an appointed Neutronics distributor in Malaysia.
Product categories
Available product types
Process Oxygen Analyzers, Trace and High Concentration Oxygen Analyzers, Other Analyzers, Handheld (Portable).

Oxytron 2000
Hover for details →
The Neutronics Oxytron 2000 is a custom-configured instrument designed to automatically control oxygen in process applications. When combined with a properly designed sample conditioning package, the Oxytron 2000 provides reliable measurement and control of oxygen, keeping it at a safe level by controlling the flow of inert gas into the process. Originally developed for one of the country's largest chemical manufacturers, the Oxytron 2000 has been proven reliable in thousands of installations and can provide control for two independent vessels or processes. The Oxytron 2000 is a microprocessor-based instrument capable of accepting multiple sensor inputs from Neutronics sensors and utilizing them to control user configurable alarms and signal outputs. Two auxiliary 4-20mA inputs enable the input of 4-20mA signals from sensors other than the oxygen sensors. Nine alarm relay contacts are provided for indication of calibration, setpoint activation, system maintenance requirements, fault conditions, and sensor comparison alarms. Two separate isolated 4-20mA current loops are provided to communicate the measurements from one or two oxygen sensors.

Compact series percent oxygen analyzer/controller. The Mini-ICS (Inert Gas Control System) is a compact series analyzer designed for continuous real-time oxygen monitoring and concentration control of nitrogen or inert gas. When combined with a properly designed sample conditioning package, the Mini-ICS provides reliable measurement of oxygen levels over a wide range of conditions and automatically maintains oxygen levels within specified limits through precise control of the flow of inert gas into the process. Inert gas blanketing protects plant personnel, products, and plant assets by reducing the oxygen content in the vapor space of a tank or process vessel. Making the vapor space inert eliminates the possibility of fire or explosion, decreases evaporation, and protects the vessel from structural corrosion damage. Tank blanketing also prevents air, moisture, or other contaminants from entering the vapor space and causing product quality degradation.

The Neutronics 1100 Percent Oxygen Analyzer is a compact analyzer for oxygen gas measurement and process control applications. Designed for a measurement range of zero to 100% oxygen, the unit features a reliable electrochemical sensor that can be mounted remotely at the sampling point to ensure a fast response time. A flow-through mounting head allows the sensor to be horizontally or vertically mounted directly into the sampled process gas stream. The CAG-250E electrochemical sensor ensures reliable performance and fast response for critical measurements. Utilizing a patented weak-acid based technology for a more stable signal and longer sensor life, this sensor can withstand high levels of CO2, CO, and other acidic gases. The CAG-250E sensor measures the partial pressure of oxygen in the gas sample. As the sample gas passes by the sensor, the oxygen is electrochemically reduced at the cathode. The current generated is directly proportional to the partial pressure of oxygen at the sensing surface of the cell. The sensor is a sealed disposable device that does not require periodic maintenance.

OA-1
Hover for details →
The Neutronics Model OA-1 is a portable analyzer that accurately measures oxygen in the range of 0.1 ppm to 100%. Featuring the Neutronics rapid response zirconium oxide sensor with its extremely fast response and high accuracy, the Model OA-1 can be exposed to air and within seconds read ppm oxygen in a variety of background gases.

OA-1S
Hover for details →
The MSA OA-1S+, powered by Neutronics Technology, is a portable analyzer that accurately measures oxygen in the range of 75 ppb to 100%. Featuring the rapid response zirconium oxide sensor with its extremely fast response and high accuracy, the Model OA-1S+ can be exposed to air and quickly read ppb oxygen in a variety of background gases.

The Neutronics 7100 Trace Oxygen Analyzer is a compact analyzer designed for trace oxygen gas measurement. This analyzer features a rapid-response mini-zirconia sensor with a measurement range of 0 to 1000 ppm oxygen. Extremely fast response, high accuracy, and no requirement for periodic calibrations make this analyzer a low-maintenance solution.



OEM120-CO
Hover for details →
Panel mounted carbon monoxide analyzer. The Neutronics OEM120-CO Carbon Monoxide Analyzer is a panel mounted analyzer that accurately measures carbon monoxide in the range of 0 to 200 ppm. Designed for continuous operation, this analyzer measures and displays the level of carbon monoxide in a workplace area.

DIN rail mounted analyzer for helium in air. The Neutronics DTX832-He Helium in Air Analyzer is for helium in air measurement. With an Ethernet digital communication interface along with 4 to 20 mA output, this analyzer combines ease of use with simple installation.

Percent oxygen analyzer, panel mounted. The Neutronics OEM 100 O2 is a panel mounted analyzer that accurately measures oxygen in the range of 0 to 20% and 0 to 25%. Designed for continuous operation, this analyzer measures and displays the level of oxygen in a workplace area.

OEM100 CO
Hover for details →
The MSA OEM 100 CO, powered by Neutronics Technology, is a wall mounted analyzer that accurately measures carbon monoxide in the range of 0 to 200 ppm. Designed for continuous operation, this analyzer measures and displays the level of carbon monoxide in a workplace area.

Legend Series™ R-1234yf/R-134a
Hover for details →
SAE-certified refrigerant analyzer for automotive applications. The Legend Series™ R-1234yf/R-134a Refrigerant Analyzer is a refrigerant identifier and analyzer for the past, present, and future. Service R-12, R-134a, and R-1234yf vehicles with one tool.

Mini ID R-134a
Hover for details →
Portable refrigerant identifier. The Neutronics Mini ID™ R-134a Refrigerant Identifier is a low-cost R-134a identification option. It helps you verify the presence and quality of R-134a refrigerant in a vehicle's air conditioning system to avoid recovering contaminated refrigerant.

Mini ID R-1234yf
Hover for details →
Handheld refrigerant identifier. The Neutronics, low cost Mini ID™ R-1234yf Refrigerant Identifier helps you verify the presence and quality of R-1234yf refrigerant in vehicle air conditioning systems. This helps you avoid potential damage to your air conditioning service equipment.