JCT Group
Explore JCT Group industrial gas analysis and measurement solutions group and related product families available through Exact Analytical in Malaysia. Compare models, applications and technical documents with local consultation, integration and service support.
Exact Analytical is an appointed JCT Group distributor in Malaysia.
Product categories
Available product types
Gas Sampling Probes, Heated Sample Lines, Sample Gas Coolers, Condensate Treatment, Sample Gas Filters, Sample Gas Pumps, Gas Conditioning Systems, NOx Converter, Flame Ionization Detector, Thermal Conductivity, Liquid Transmitter/Sensor, Watercut Meters/BS&W Analyzers.

Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Weather protection housing (option). Various options and upgrades. Wide range of accessories. Full bore ball valve for process shut-off (option). Manual and actuator operation of ball valve (option).
Applications
Technical Specifications
Models & Variants

Temperature control by steam pressure. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Weather protection housing (option). Various options and upgrades. Wide range of accessories. Full bore ball valve for process shut-off (option). Manual and actuator operation of ball valve (option).
Applications
Technical Specifications
Models & Variants

Homogeneous heating without cold spots. Filtration from outside to inside. Filter element change without tools. Self limiting PTC heater. Temperature status contact. Weather protection housing. Wide range of accessories. Calibration port (option).
Applications
Technical Specifications
Models & Variants

Homogeneous heating without cold spots. Filtration from outside to inside. Filter element change without tools. Self limiting PTC heater. Temperature status contact. Weather protection housing. Wide range of accessories. Calibration port (option). Back purge port (option). Field and factory tested.
Applications
Technical Specifications
Models & Variants

Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Electronic temperature controller including over temperature protection. Temperature status contact. Weather protection housing. Various options and upgrades. Wide range of accessories.
Applications
Technical Specifications
Models & Variants

Full bore ball valve for process shut-off. Manual and actuator operation of ball valve. Homogeneous heating without cold spot. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Electronic temperature controller including over temperature protection. Temperature status contact. Weather protection housing. Various options and upgrades. Wide range of accessories.
Applications
Technical Specifications
Models & Variants

Modular design for custom-tailored applications. Highly efficient filter cleaning. Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Electronic temperature controller including over temperature protection. Temperature status contact. Weather protection housing. Various options and upgrades. Wide range of accessories. Integrated back flush / back purge controller (option).
Applications
Technical Specifications
Models & Variants

Modular design for custom-tailored applications. Highly efficient filter cleaning. Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Electronic temperature controller including over temperature protection. Temperature status contact. Weather protection housing. Various options and upgrades. Wide range of accessories. Integrated back flush / back purge controller (option).
Applications
Technical Specifications
Models & Variants

Homogeneous heating of the sampling probe up to 315 °C without cold spots. No clogging of probe or connected line. Self cleaning effect due to dissolving of ammonia salts in accumulated condensate. Weather protection housing for outdoor installation. ABS filter with freeze protection or heater (optionally). Large active filter surface (170 cm²). Electronic temperature controller. Filtration from outside to inside. Temperature status contact. Wide range of accessories. Integrated purge controller (optionally).
Applications
Technical Specifications
Models & Variants

Different dilution ratio and consumptions of dilution gas available. Modular design for custom-tailored applications. Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Different material of filter elements. Optional over temperature sensor. Temperature status contact. Weather protection housing. Integrated back purge control unit (option).
Applications
Technical Specifications
Models & Variants

In robust weatherproof FRP housing. For wall mounting. PLC (programmable logic controller). Adjustable interval for back purge cycles. Status contact. Safety shut-off valve. Control for process shut-off valve.
Applications
Technical Specifications
Models & Variants

Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Self limiting PTC heater. Weather protection housing. Low temperature status contact (intrinsically save). Various options and upgrades. Wide range of accessories.
Applications
Technical Specifications
Models & Variants

Full bore ball valve for process shut-off. Manual and actuator operation of ball valve. Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Self limiting PTC heater. Weather protection housing. Low temperature status contact (intrinsically save). Various options and upgrades. Wide range of accessories.
Applications
Technical Specifications
Models & Variants

Modular design for custom-tailored applications. Highly efficient filter cleaning. Homogeneous heating without cold spots. Large active filter surface. Filtration from outside to inside. Filter element change without tools. Different material of filter elements. Self-limiting heater for T3 or T4. Temperature status contact. Weather protection housing. Various options and upgrades. Wide range of accessories.
Applications
Technical Specifications
Models & Variants

In robust weatherproof stainless steel housing. For wall mounting. Lockable housing. Integrated pressure regulator for inert gas or compressed air. 2 explosion-proof solenoid valves (safety shut-off valve and clocked back purge valve). Manual shut-off ball valve in the inlet. External PLC (programmable logic controller) with adjustable interval for back purge cycles and status contact for mounting in explosion-free area as option.
Applications
Technical Specifications
Models & Variants

Wide range of different sampling pipe and pre-filter materials. Wide range of different sampling pipe and pre-filter lengths. All sampling pipes and pre-filters with G 3/4" male connection thread. Wide range of different extension tubes for pre-filter placement in the process. Pre-filter also with v-deflector for protection against abrasion. All sampling pipes and pre-filters with mounting hexagon.
Applications
Technical Specifications
Models & Variants

Corrosion resistant double shell pipe with internal heating. Heating failure monitoring with alarm contact and indication. Mounting directly at the standard process flanges. Tube length of 500 to 2000 mm available. Controlled heating up to 180 °C. Electronic temperature controller with temperature display. Controller for wall mounting or directly mounted at the sampling pipe (option). Electrical connection turn-key mounted with JTC-308.
Applications
Technical Specifications
Models & Variants

Corrosion resistant stainless steel pipe. Fully electronic temperature controller with low temperature alarm and excess temperature switch-off. Error message for sensor short-circuit and broken sensor. Mounting directly at the standard process and gas sampling probe flange. Pipe length 400 mm. Temperature adjustment range 5 °C to 200 °C, optionally 5 °C to 320 °C. Sampling pipes of arbitrary length can be screwed in on process side. Back purge connection with check valve.
Applications
Technical Specifications
Models & Variants

Very small outlines. Very small built-in valve in 1/8" adapter. Two in one solution: valve and connector.
Applications
Technical Specifications
Models & Variants

Robust, compact transport case with all necessary parts for mobile gas sampling: gas sampling probe, heated sample line, sampling tubes, filter elements, calibration gas connection, mounting chains, ... Compact gas sampling probe with operation and temperature status LEDs. Homogeneous heating to 180 °C without cold spots. Gas sampling probe with self limiting PTC heating element. Calibration gas connection at the gas sampling probe. Heated sample line JHSo with integrated temperature controller and operation status LED. All electric connection cables are integrated in the heated sample line. Exclusively Quick-On connectors for all gas connections. Flexible, lightweight and robust heated sample line. Comprehensive list of options for various applications.
Applications
Technical Specifications
Models & Variants

Maintain temperature up to 120 °C. External jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. Maximum length of heated line: 65 m. Inner core: PTFE, PFA or SS316, DN 4 to DN 8. Complete assembling sets with connection cable and silicone end caps or ready for use ex works. Second core for e.g. calibration gas as option.
Applications
Technical Specifications
Models & Variants

Maintain temperature regulated up to 185 °C. External jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. Ready for use. Interchangeable inner core for JHER. Second core for e.g. calibration gas as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Regulated heatable to max. 200 °C. External protection corrugated jacket of Polyamide. Heat insulation with thermo fleece. Ready for use. Interchangeable inner core for JH3FR. Second core for e.g. calibration gas as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Regulated heatable to max. 200 °C. External jacket flexible protection braid of polyamide. Heat insulation with silicone foam. Ready for use. Very flexible. Interchangeable inner core for JH3FGR. Second core for e.g. calibration gas as option. Integrated temperature controller as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Maintain temperature up to 120 °C. External jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. Maximum length of heated line: 65 m. Inner core: PTFE, PFA or SS316, DN 4 to DN 8. Complete assembling sets with connection cable and silicone end caps or ready for use ex works. Second core for e.g. calibration gas as option.
Applications
Technical Specifications
Models & Variants

Operating temperature regulated up to 180 °C. Antistatic external jacket of corrugated polyamide PA12. Heat insulation with thermo fleece. 2 x Ex-Pt100 temperature sensors. Ready for use. Second core for e.g. calibration gas as option. Inner core reinforced with stainless steel braid.
Applications
Technical Specifications
Models & Variants

Ready for use. Wide thermal application area. Non flammable. With and without calibration gas core. Suitable for Ex zones.
Applications
Technical Specifications
Models & Variants

Heated JCT sample lines JH3F(R) and JH3FG(R) with integrated filter. Completely heated up to 200 °C. Filter housing stainless steel SS316Ti (PTFE- coated or Hastelloy as option). Ceramic filter element (5 um or 20 um). Jacket PA-corrugated hose or PA-braid. Fixed or interchangeable core. Completely assebled. Ready for connection with temperature controllers series HT.
Applications
Technical Specifications
Models & Variants

Ready for use combination of digital temperature controller JPXE4 and Solid State Relay. RGC with up to 30 A switching capacity. 4-digits LED-indication of set point and actual value For PT 100 and thermocouples JPXE4 for front panel mounting or optional for wall or rail mounting Solid State Relay RGC for rail mounting For single and 3 phase application SSR with varistor protection output Self-lifting terminals.
Applications
Technical Specifications
Models & Variants

Controller and limiter in one device. Status / Alarm contact. Suitable for self-regulating trace heaters. Suitable for resistance trace heaters.
Applications
Technical Specifications
Models & Variants
View all 93 model links
- JES-301W
- JES-301G
- JES-301L
- JES-301LM
- JES-301
- JES-301V
- JES-360
- JES-360H
- JES-370
- JES-380
- JES-301K
- JES-301E1
- JES-301E1SV
- JES-360Ex
- JES-301KE1
- JER & JHD
- JER-EH
- JHPF
- JBPRV
- JPEX
- JH3BE
- JH3E & JH3ER
- JH3F & JH3FR
- JH3FG & JH3FGR
- JH3BEX
- JH3EX
- JISLC
- JHAF
- JPXE4
- JTC-100 Ex
- HT-61 / HT-62
- HT-63
- JTC-419 / JTC-419E
- JCS-100
- JCT-1 & JCT-2
- JCT-3
- JCM-300
- JCM-310 / JCMF-310
- JCM-320
- JCM-3PC
- JSR-25
- KW-2
- JKS-10
- 11-LD
- JCPS
- JGWU & JGWUH
- JF-1
- JAF-1
- JSF-1
- JSF-2
- JBF-301L
- JSP-100
- JSP-200
- JSP-83 / JSP-86 KTE / JSP-89
- JSP-87EX
- JCL-301
- JCL-304 / JCL-319
- JCC-R / JCC-Q/ JCC- P / JCC-L
- JCP-300
- JNOX
- JFID-FE TOC
- JFID-FE
- JFID-MK
- JFID-ES THC
- JFID-PT THC
- JFID-Series
- JTCD-300
- FTC-130TRA
- JLT
- JLS
- JLTX
- JLSX
- ZT-100 F-Series
- ZT-100 S-Series
- ZTMX
- ZT-100 I-Series
- Sample Coolers (SC)
- Tube in Tube Sample Cooler (TIT)
- Cation Resin Column (CR)
- Back Pressure Relief Valve (BPR)
- High Pressure Reducer Valve (HPRV)
- Thermal Shut-Off Valve (5TVS)
- Degassed Cation Conductivity (DG-50)
- Degassed Cation Conductivity (DG-105)
- Water Cooling Temperature Control Unit (TCU)
- Multi-Streams Analyzer Sequencer (SQ/MF)
- Compact Conditioning Panel (CP)
- Isokinetic Steam Sample Probe (ISP)
- Standard Sample Probe (SSP)
- Needle System Adapter for Standard GL45 Bottle
- Fixed Volume Sample Cylinders
- Block Selector System with two Valves
- Dead Man System